The Military Engineer Services has published a tender for "To carryout urgent repairs to defective acb of ncn data centre at NTS Teylerabad under GE Minniebay" on the 22 Dec 2025. This tender belongs to Air Force Station Repair category. This tender is published in South Andaman, Andaman and Nicobar Islands location. The vendors interested in this tender and related Air Force Station Repair tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: building maintenance Tenders | non residential buildings Tenders | all civil works Tenders
Related categories: Barrage cum Bridge Tenders | Airport Runway Repair Tenders | Road Paving Tenders |
MES issued 18,839 tenders for Air Force Station Repair last year
With, 1124 floated just last month.
| Tender Title | To carryout urgent repairs to defective acb of ncn data centre at NTS Teylerabad under GE Minniebay |
|---|---|
| Tender Description | m&l for dismantling the cable connections of four pole/ three pole air circuit breaker of capacity 1000 amps ,415 v 50 hz of siemens make, opening the air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) cleaning the insulation parts including bushings with crc solution.b) checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manualc) check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. replace the worn-out parts. d) check arc chutes for damage.e) checking/inspecting shunt trip coil & under voltage coil for serviceability and replacing the same if required. f) check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functionalnote : the rate quote |
| Comments | m&l for dismantling the cable connections of four pole/ three pole air circuit breaker of capacity 1000 amps ,415 v 50 hz of siemens make, opening the air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) cleaning the insulation parts including bushings with crc solution.b) checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manualc) check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. replace the worn-out parts. d) check arc chutes for damage.e) checking/inspecting shunt trip coil & under voltage coil for serviceability and replacing the same if required. f) check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functionalnote : the rate quote |
| Published Date | |
|---|---|
| Due Date | 27 Dec 2025 00:00:00 |
| Estimated Value | 1.69 Lakh |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |