The NOU has published a tender for "Tender Notice-Dept. of Chemistry" on the 14 Mar 2020. This tender belongs to Fluorescence spectrophotometer category. This tender is published in Mayurbhanj, Odisha location. The vendors interested in this tender and related Fluorescence spectrophotometer tenders can obtain further details by registering in the Tendersniper web portal. Upon registration, Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: laboratory procurements Tenders | test and measuring instruments Tenders | spectrometers Tenders
Related categories: Ferromagnetic Resonance Spectrometer Tenders | Spectrofluorimeters or fluorimeters Tenders | Bio spectrometer Tenders |
Around 7131 tenders were floated in Odisha in the past month with major spending on road repair Tenders, road construction Tenders, road relaying Tenders
Tender Title | Tender Notice-Dept. of Chemistry |
---|---|
Tender Description | 1. fluorescence spectrophotometerspecifications:1. monochromator czerny-turner or equivalent2. source pulsed xenon lamp. the source should be on only during sample reading to avoidcontinuous exposure causing photo-degradation of sensitive samples. peak power equivalentto 75 kw.& long life system must have room light immunity to sample compartment forsmooth analysis3. grating excitation: 1200 lines/mm, blazed at 370 nm emission: 1200 lines/mm, blazed at 440 nm4. high performance pmt5. spectral bandwidth excitation and emission: 1.5 – 20 nm6. sensitivity raman band of water: > 500:1 rms, 500 nm excitation > 750:1 rms, 350 nmexcitation7. resolution 1.5 nm filters excitation: computer selectable including 2 bandpass, 2 cutoff, ashutter and open beam position 28. wavelength range 190-1100 nm9. wavelength accuracy ± 1.5 nm10. should provide user friendly software which must operate on microsoft windows xp.11. the system must include minimum two quartz cuvettes. sensitivity-detect picomolar a |
Comments | 1. fluorescence spectrophotometerspecifications:1. monochromator czerny-turner or equivalent2. source pulsed xenon lamp. the source should be on only during sample reading to avoidcontinuous exposure causing photo-degradation of sensitive samples. peak power equivalentto 75 kw.& long life system must have room light immunity to sample compartment forsmooth analysis3. grating excitation: 1200 lines/mm, blazed at 370 nm emission: 1200 lines/mm, blazed at 440 nm4. high performance pmt5. spectral bandwidth excitation and emission: 1.5 – 20 nm6. sensitivity raman band of water: > 500:1 rms, 500 nm excitation > 750:1 rms, 350 nmexcitation7. resolution 1.5 nm filters excitation: computer selectable including 2 bandpass, 2 cutoff, ashutter and open beam position 28. wavelength range 190-1100 nm9. wavelength accuracy ± 1.5 nm10. should provide user friendly software which must operate on microsoft windows xp.11. the system must include minimum two quartz cuvettes. sensitivity-detect picomolar a |
Published Date | |
---|---|
Due Date | 06 Apr 2020 00:00:00 |
Estimated Value | 0.0 |
---|---|
EMD | 0 INR |
Processing Fee | 0 INR |