The Ministry of Power has published a tender for "Custom Bid for Services - 200147314 Engaging consultant for performance improvement in stage-2 CT of NTPC Ramagundam" on the 20 Nov 2025. This tender belongs to Cooling tower category. This tender is published in Peddapalle, Telangana location. The vendors interested in this tender and related Cooling tower tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: cooling towers Tenders | all types of coolers Tenders | industrial fans Tenders
Related categories: Split air conditioner Tenders | Split AC Repair Tenders | Air Conditioner Spares Tenders |
In Peddapalle district, Telangana, a total of 0 Cooling tower tenders have been published, with
| Tender Title | Custom Bid for Services - 200147314 Engaging consultant for performance improvement in stage-2 CT of NTPC Ramagundam |
|---|---|
| Tender Description | at ntpc ramagundam, stage-2 units (3x 500 mw) there are six cooling towers of recondomake. the details of stage-2 cooling towers are as follows1. type of cooling tower: counter flow induced draft2. total no. of cooling towers: 6 (six)3. type of fill: splash fill (pp grid type splash fills)4. quantity of water cooled per cooling tower (cu.m/hr): 30,0005. no of cells per tower: 16 (14 working + 2 standby)6. design hot water temperature: 43 deg c7. design cold water temperature: 32 deg c8. design fan motor power / cell: 65.0 kw9. design approach: 4 deg c10. shortfall in cold water temperature 3.18 deg c. |
| Comments | at ntpc ramagundam, stage-2 units (3x 500 mw) there are six cooling towers of recondomake. the details of stage-2 cooling towers are as follows1. type of cooling tower: counter flow induced draft2. total no. of cooling towers: 6 (six)3. type of fill: splash fill (pp grid type splash fills)4. quantity of water cooled per cooling tower (cu.m/hr): 30,0005. no of cells per tower: 16 (14 working + 2 standby)6. design hot water temperature: 43 deg c7. design cold water temperature: 32 deg c8. design fan motor power / cell: 65.0 kw9. design approach: 4 deg c10. shortfall in cold water temperature 3.18 deg c. |
| Published Date | |
|---|---|
| Due Date | 25 Nov 2025 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |