The National Thermal Power Corporation Limited has published a tender for "10_M9438156025_NTPC Korba,20_M9438156025_NTPC Bongaigaon,30_M9438156025_NTPC Barh,40_M9438406006_NT" on the 05 Apr 2022. This tender belongs to Power generation unit category. This tender is published in Bilaspur, Chhattisgarh location. The vendors interested in this tender and related Power generation unit tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: floating solar anchoring system Tenders | green hydrogen Tenders | mechanical items Tenders
In Bilaspur district, Chhattisgarh, a total of 0 Power generation unit tenders have been published, with
Tender Title | 10_M9438156025_NTPC Korba,20_M9438156025_NTPC Bongaigaon,30_M9438156025_NTPC Barh,40_M9438406006_NT |
---|---|
Tender Description | 10-m9438156025- pr-100206700(for ntpc korba)specifications for wet bulb and dry bulb temperature transmitter along withrelative hunidity for outdoor application:1.measurement of wet bulb temperature, range -40 … +60 °c2.measurement of relative humidity, range 0 ... 100 %rh3.measurement of dry bulb temperature, range -40 … +60 °c4.humidity accuracy, 0 … 90 %rh, ±2 %rh , 90 … 100 %rh, ±3 %rh5.wet bulb and dry bulb temperature accuracy ±0.5 °c6.minimum 2 no of outputs of 4 … 20 ma for wet bulb temp (preferabally) or dry bulbtemperature & relative humidity, loop powered.7.supply voltage 20 … 28vdc8.ip rating ip65 or better9.operating temperature -40 … +60 °c10.operating humidity 0 … 100 %rh maximum11.wind/flow speed 30 m/s (67 mph)12.vendor has to supply all the mounting accessories along withtransmitters.calibration: the equipment will be accepted only if accompanied with calibrationcertificate of manufacturer/nabl accredited lab.warranty: minimum 1 year from date of supply on main instru |
Comments | 10-m9438156025- pr-100206700(for ntpc korba)specifications for wet bulb and dry bulb temperature transmitter along withrelative hunidity for outdoor application:1.measurement of wet bulb temperature, range -40 … +60 °c2.measurement of relative humidity, range 0 ... 100 %rh3.measurement of dry bulb temperature, range -40 … +60 °c4.humidity accuracy, 0 … 90 %rh, ±2 %rh , 90 … 100 %rh, ±3 %rh5.wet bulb and dry bulb temperature accuracy ±0.5 °c6.minimum 2 no of outputs of 4 … 20 ma for wet bulb temp (preferabally) or dry bulbtemperature & relative humidity, loop powered.7.supply voltage 20 … 28vdc8.ip rating ip65 or better9.operating temperature -40 … +60 °c10.operating humidity 0 … 100 %rh maximum11.wind/flow speed 30 m/s (67 mph)12.vendor has to supply all the mounting accessories along withtransmitters.calibration: the equipment will be accepted only if accompanied with calibrationcertificate of manufacturer/nabl accredited lab.warranty: minimum 1 year from date of supply on main instru |
Published Date | |
---|---|
Due Date | 19 Apr 2022 00:00:00 |
Estimated Value | 0.0 |
---|---|
EMD | 0 INR |
Processing Fee | 0 INR |