The SKUAST has published a tender for "SITC of HAVC system for Establishment of Medical Centre at Main Campus Shalimar SKUAST-Kashmir" on the 27 Jun 2024. This tender belongs to Hospital construction service category. This tender is published in Srinagar, Jammu and Kashmir location. The vendors interested in this tender and related Hospital construction service tenders can obtain further details by registering in the Tendersniper web portal. Upon registration, Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: non residential buildings Tenders | all civil works Tenders | non residential buildings construction Tenders
Related categories: Bank Building Construction Tenders | Bank Repair Tenders | Fire Station Construction Tenders |
In Srinagar district, Jammu and Kashmir, a total of 628 Hospital construction service tenders have been published, with 27 tenders released last month.
Tender Title | SITC of HAVC system for Establishment of Medical Centre at Main Campus Shalimar SKUAST-Kashmir |
---|---|
Tender Description | supply installation, testing & commissioning of variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll/twin rotary compressor(s), microprocessor based controller, minimum 2 compressors above 14hp module, top discharge type condensing unit(s), with r 410 a refrigerant, vibration isolators, with suitable foundation etc. complete as required. the unit shall deliver the rated capacity at ahri conditions and work even at 50°c ambient temperature without tripping. the unit shall be suitable to work on 400v +/- 10%, 3 phase, 50hz ac power supply. the unit shall be filled with first charge of the refrigerant and ready for use as required. the cop at ahri conditions shall not be less than 3.1 and ieer not less than 6.5 . makes:- o- general/toshiba/carrier/mitsubishi electric/hitachi suppl |
Comments | supply installation, testing & commissioning of variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll/twin rotary compressor(s), microprocessor based controller, minimum 2 compressors above 14hp module, top discharge type condensing unit(s), with r 410 a refrigerant, vibration isolators, with suitable foundation etc. complete as required. the unit shall deliver the rated capacity at ahri conditions and work even at 50°c ambient temperature without tripping. the unit shall be suitable to work on 400v +/- 10%, 3 phase, 50hz ac power supply. the unit shall be filled with first charge of the refrigerant and ready for use as required. the cop at ahri conditions shall not be less than 3.1 and ieer not less than 6.5 . makes:- o- general/toshiba/carrier/mitsubishi electric/hitachi suppl |
Published Date | |
---|---|
Due Date | 15 Jul 2024 00:00:00 |
Estimated Value | 53.3 Lakh |
---|---|
EMD | 0 INR |
Processing Fee | 0 INR |