The JKPDD has published a tender for "EDR/53 OF 2025-26" on the 16 Oct 2025. This tender belongs to Hardware category.  This tender is published in Rajouri, Jammu and Kashmir location. The vendors interested in this tender and related Hardware tenders can obtain further details by exploring  Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
              
Related alert:  hardware components Tenders  |  manufacturing components and supplies Tenders  |  stellas intertraders tenders Tenders 
            
Around 6905 tenders were floated in Jammu and Kashmir in the past month with major spending on road construction Tenders, drain construction Tenders, public toilet construction Tenders
| Tender Title | EDR/53 OF 2025-26 | 
|---|---|
| Tender Description | creation of 100kva substations along with htlt network at gurdan pain subdivision rajouri-i. sitc of ht line s.t pole 9 mtrs long (410-sp33) galvanisied v cross-arm with top bracket including clamp 30 mm2 acsr weasel conductor pg clamp for 30 mm2 acsr weasel conductor 11 kv pin insulators with pins (10kn) 11 kv disc insulators with fittings (45 kn) earthing complete by g.i. pipe 40mm or g.i. rod 20mm 2.5mtr long through g.i. cemment bottoming 1:2:4 mix as per rec standard 0.5 cubic mtr per poles galvansied stay set with 50x8mm stay clamp, guy insulator (02nos.) anchor plate (200x200x6mm) nut bolts, 2nos. turn bukles, 1.8m long 16mm diameter solid gs stay rod & 7/3.15 mm dia gi stranded wire complete al. painting red oxide anti climbing device with clamps danger plates with clamps galvansied nuts and bolts of sorts sitc of 11/0.44 kv s/station 100kva transformer level ii , 11/0.433kv,3-phase distribution transformer with bimetallic terminal connectors ,almunium wound and with lv | 
| Comments | creation of 100kva substations along with htlt network at gurdan pain subdivision rajouri-i. sitc of ht line s.t pole 9 mtrs long (410-sp33) galvanisied v cross-arm with top bracket including clamp 30 mm2 acsr weasel conductor pg clamp for 30 mm2 acsr weasel conductor 11 kv pin insulators with pins (10kn) 11 kv disc insulators with fittings (45 kn) earthing complete by g.i. pipe 40mm or g.i. rod 20mm 2.5mtr long through g.i. cemment bottoming 1:2:4 mix as per rec standard 0.5 cubic mtr per poles galvansied stay set with 50x8mm stay clamp, guy insulator (02nos.) anchor plate (200x200x6mm) nut bolts, 2nos. turn bukles, 1.8m long 16mm diameter solid gs stay rod & 7/3.15 mm dia gi stranded wire complete al. painting red oxide anti climbing device with clamps danger plates with clamps galvansied nuts and bolts of sorts sitc of 11/0.44 kv s/station 100kva transformer level ii , 11/0.433kv,3-phase distribution transformer with bimetallic terminal connectors ,almunium wound and with lv | 
| Published Date | |
|---|---|
| Due Date | 22 Oct 2025 00:00:00 | 
| Estimated Value | 0.0 | 
|---|---|
| EMD | 0 INR | 
| Processing Fee | 0 INR |