The Military Engineer Services has published a tender for "SPECIAL REPAIRS REPLACEMENT AGAINST BER TRANSFORMER AT AGE BR DETT-A AND PROVN OF GEYSERS AT UPPER NARIAN UNDER AGE EM OF GE 862 EWS" on the 30 Mar 2026. This tender belongs to Air Force Station Repair category. This tender is published in Udhampur, Jammu and Kashmir location. The vendors interested in this tender and related Air Force Station Repair tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related categories: Airport Runway Tenders | Airport Runway Repair Tenders | Road Paving Tenders |
In Udhampur district, OTHERS, a total of 358 Air Force Station Repair tenders have been published, with 28 tenders released last month.
| Tender Title | SPECIAL REPAIRS REPLACEMENT AGAINST BER TRANSFORMER AT AGE BR DETT-A AND PROVN OF GEYSERS AT UPPER NARIAN UNDER AGE EM OF GE 862 EWS |
|---|---|
| Tender Description | supply, install ,testing and commissioning of distribution transformer stepdown 11 kv/0.433 kv three phase complying with is : 1180(pt-i) 2014 with latest ammendments outdoor type double copper wound suitable for 50 hz system of capacity 63 kva ,oil immersed naturally cooled delta connected on ht side and star connected on lt side ,vector group dyn ii, provided with off load tap changer to vary secondary voltage from -7.5% to +7.5 % in step of 2.5 % losses should be confirmed to the limits specified as follows maximum allowable losses at full load (100%) & half load (50%) shall not be exceeded 0.98% & 0.70% ,percentage impedence 5 % losses and impedance are subjected to tolerance as specified in is 1180. the transformer shall be supplied with first filling of oil confirming to is 335. the transformer shall have both side cable end box with neutral brought out complete all as directed by engr-in-charge and installation of transformer shall be carried out as per is 10028 and comprising |
| Comments | supply, install ,testing and commissioning of distribution transformer stepdown 11 kv/0.433 kv three phase complying with is : 1180(pt-i) 2014 with latest ammendments outdoor type double copper wound suitable for 50 hz system of capacity 63 kva ,oil immersed naturally cooled delta connected on ht side and star connected on lt side ,vector group dyn ii, provided with off load tap changer to vary secondary voltage from -7.5% to +7.5 % in step of 2.5 % losses should be confirmed to the limits specified as follows maximum allowable losses at full load (100%) & half load (50%) shall not be exceeded 0.98% & 0.70% ,percentage impedence 5 % losses and impedance are subjected to tolerance as specified in is 1180. the transformer shall be supplied with first filling of oil confirming to is 335. the transformer shall have both side cable end box with neutral brought out complete all as directed by engr-in-charge and installation of transformer shall be carried out as per is 10028 and comprising |
| Published Date | |
|---|---|
| Due Date | 20 Apr 2026 00:00:00 |
| Estimated Value | 44.59 Lakh |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |