The Multi-State has published a tender for "Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 0 TO 60 kM,Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 61 TO 180 Km,Transportation of transformer up to 3 phase 63 kVA to a following specified distance 181 TO 350 kM,Arrangement of repaired and refurbished 3 Ph upto 63 kVA similar to the faulty 0 TO 25 kVA 11kV 440V Transformer,Arrangement of repaired and refurbished 3 Ph transformer upto 63 kVA similar to the faulty 26KVA-63 kVA 11kV 440V Transformer,Supplying and of three piece nonlinear resistor type lightning arrestor,Supplying and of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required,Supplying and 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings,11 KV triple pole 200 A rating A B Switch suitable for vertical mounting with three 11 kV Polymeric Insulator on 75 by 40 mm M S Channels,Transformer oil HV grade wit" on the 17 Dec 2025. This tender belongs to Transformer Services category. This tender is published in Dimapur, Nagaland location. The vendors interested in this tender and related Transformer Services tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: transformers Tenders | electrical system services Tenders | electrical equipments Tenders
Related categories: Manufacturing Equipment Repair Tenders | Engineering Equipment Servicing Tenders | Packaging Machine Maintenance Tenders |
In Dimapur district, Nagaland, a total of 0 Transformer Services tenders have been published, with
| Tender Title | Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 0 TO 60 kM,Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 61 TO 180 Km,Transportation of transformer up to 3 phase 63 kVA to a following specified distance 181 TO 350 kM,Arrangement of repaired and refurbished 3 Ph upto 63 kVA similar to the faulty 0 TO 25 kVA 11kV 440V Transformer,Arrangement of repaired and refurbished 3 Ph transformer upto 63 kVA similar to the faulty 26KVA-63 kVA 11kV 440V Transformer,Supplying and of three piece nonlinear resistor type lightning arrestor,Supplying and of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required,Supplying and 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings,11 KV triple pole 200 A rating A B Switch suitable for vertical mounting with three 11 kV Polymeric Insulator on 75 by 40 mm M S Channels,Transformer oil HV grade wit |
|---|---|
| Tender Description | transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 0 to 60 km , transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 61 to 180 km , transportation of transformer up to 3 phase 63 kva to a following specified distance 181 to 350 km , arrangement of repaired and refurbished 3 ph upto 63 kva similar to the faulty 0 to 25 kva 11kv 440v transformer , arrangement of repaired and refurbished 3 ph transformer upto 63 kva similar to the faulty 26kva-63 kva 11kv 440v transformer , supplying and of three piece nonlinear resistor type lightning arrestor , supplying and of 11 kv pin insulator complete with large steel head g i pin nuts washers etc as required , supplying and 11 kv disc insulator for 11 kv over head lines with galvanised insulator /item category fittings , 11 kv triple pole 200 a rating a b switch suitable for vertical mounting with three 11 kv polymeric insulator on 75 by 40 m |
| Comments | transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 0 to 60 km , transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 61 to 180 km , transportation of transformer up to 3 phase 63 kva to a following specified distance 181 to 350 km , arrangement of repaired and refurbished 3 ph upto 63 kva similar to the faulty 0 to 25 kva 11kv 440v transformer , arrangement of repaired and refurbished 3 ph transformer upto 63 kva similar to the faulty 26kva-63 kva 11kv 440v transformer , supplying and of three piece nonlinear resistor type lightning arrestor , supplying and of 11 kv pin insulator complete with large steel head g i pin nuts washers etc as required , supplying and 11 kv disc insulator for 11 kv over head lines with galvanised insulator /item category fittings , 11 kv triple pole 200 a rating a b switch suitable for vertical mounting with three 11 kv polymeric insulator on 75 by 40 m |
| Published Date | |
|---|---|
| Due Date | 07 Jan 2026 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |