The National Mineral Development Corporation has published a tender for "BOQ (SPARES OF CT AND PT OF SIEMENS MAKE)::.Current Transformer -->Current Transformer
- 4MC4_90 – Ring core type
- Standard: IEC60044-1
- Insulation Class: E
- Rated insulation level of secondary winding: 3kV AC, 1 Min.
- Rated Freq.: 50 Hz
- Overload: 120% cont. of rated current
- Rated Thermal short time withstand current Ith: 40kA/3 Sec
Core -1 :
2500-1250A/1A, Class – PS-PS, Vk >500V-250V, Rct<15-7.5 Ohms, Im <30-60mA at Vk/2
Core 2:
2500-1250A/1A, Class – 5P20-5P20, 15VA-15VA, Rct<15-7.5 Ohms
Core 3:
2500-1250A/1A, Class – 0.5-0.5, 10VA-10VA, ISF<5.5
Core 4:
2500-1250A/1A, Class – PS-PS, Vk >600V-300V,
Rct<15-7.5 Ohms, Im <30-60mA at Vk/2
Suitable for 33kV GIS Type 8DA10/8DB10 of SIEMENS MAKE
Current Transformer -->Current Transformer
- 4MC4_90 – Ring core type
- Standard: IEC60044-1
- Insulation Class: E
- Rated insulation level of secondary winding: 3kV AC, 1 Min.
- Rated Freq.: 50 Hz
- Overload: 120% cont. of rated current
- Rated Thermal short time withstand current Ith: 40kA/3 Sec
Core -1 :
2500-1250A/1A, Class –" on the 06 Nov 2021. This tender belongs to Current transformer category. This tender is published in Hyderabad, Telangana location. The vendors interested in this tender and related Current transformer tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: electrical equipments Tenders | transformers Tenders | Current Transformer Tenders
Related categories: Distribution power transformers Tenders | 25KV Distribution Transformer Tenders | 11KV / 433V Distribution Transformer Tenders |
NMDC issued 2 tenders for Current transformer last year
With, 0 floated just last month.
| Tender Title | BOQ (SPARES OF CT AND PT OF SIEMENS MAKE)::.Current Transformer -->Current Transformer - 4MC4_90 – Ring core type - Standard: IEC60044-1 - Insulation Class: E - Rated insulation level of secondary winding: 3kV AC, 1 Min. - Rated Freq.: 50 Hz - Overload: 120% cont. of rated current - Rated Thermal short time withstand current Ith: 40kA/3 Sec Core -1 : 2500-1250A/1A, Class – PS-PS, Vk >500V-250V, Rct<15-7.5 Ohms, Im <30-60mA at Vk/2 Core 2: 2500-1250A/1A, Class – 5P20-5P20, 15VA-15VA, Rct<15-7.5 Ohms Core 3: 2500-1250A/1A, Class – 0.5-0.5, 10VA-10VA, ISF<5.5 Core 4: 2500-1250A/1A, Class – PS-PS, Vk >600V-300V, Rct<15-7.5 Ohms, Im <30-60mA at Vk/2 Suitable for 33kV GIS Type 8DA10/8DB10 of SIEMENS MAKE Current Transformer -->Current Transformer - 4MC4_90 – Ring core type - Standard: IEC60044-1 - Insulation Class: E - Rated insulation level of secondary winding: 3kV AC, 1 Min. - Rated Freq.: 50 Hz - Overload: 120% cont. of rated current - Rated Thermal short time withstand current Ith: 40kA/3 Sec Core -1 : 2500-1250A/1A, Class – |
|---|
| Published Date | |
|---|---|
| Due Date | 20 Nov 2021 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |