The Postgraduate Institute of Medical and Education and Research Chandigarh has published a tender for "Replacement of ducts and diffusers inside the corridor area at Level 2 ATC Connecting to the floor mounted AHU installed inside Room No 207 PGIMER Chandigarh Composite Work SH HVAC Work Elect Work" on the 28 Feb 2026. This tender belongs to HVAC category. This tender is published in Chandigarh, Chandigarh location. The vendors interested in this tender and related HVAC tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: hvac Tenders | all types of air conditioner Tenders | all civil works Tenders
Related categories: HVAC Piping Construction Tenders | HVAC Solar Energy Construction Tenders | HVAC Refrigeration Construction Tenders |
Chandigarh Postgraduate Institute of Medical Education and Research issued 11 tenders for HVAC last year
With, 0 floated just last month.
| Tender Title | Replacement of ducts and diffusers inside the corridor area at Level 2 ATC Connecting to the floor mounted AHU installed inside Room No 207 PGIMER Chandigarh Composite Work SH HVAC Work Elect Work |
|---|---|
| Tender Description | rac component 2 way valve (pn-16) with actuator and temperature controller (insulated)supply, installation testing and commissioning of following sizes electronic, self-balancing, dynamic balancing valve with integrated 2 way modulating control valve in a single body. the actuator shall be capable of accepting upto 10 v dc and upto 20 ma electric signal and shall provide similar transducer feedback output to control system. maximum close off pressure shall not be less than 6 bar for upto 50 mm valves and 7 bar for 65 mm & above. valves should have pressure rating of 25 bar minimum. 65 mm providing & fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. providing & fixing in position the mercury in glass industrial type thermometers. p/f in position the following gi "b" class piping cut to required length and installed with welded joints including all necessary fittings such as elbows, tees etc. (as per is: 1239 part-1 (1990) wi |
| Comments | rac component 2 way valve (pn-16) with actuator and temperature controller (insulated)supply, installation testing and commissioning of following sizes electronic, self-balancing, dynamic balancing valve with integrated 2 way modulating control valve in a single body. the actuator shall be capable of accepting upto 10 v dc and upto 20 ma electric signal and shall provide similar transducer feedback output to control system. maximum close off pressure shall not be less than 6 bar for upto 50 mm valves and 7 bar for 65 mm & above. valves should have pressure rating of 25 bar minimum. 65 mm providing & fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. providing & fixing in position the mercury in glass industrial type thermometers. p/f in position the following gi "b" class piping cut to required length and installed with welded joints including all necessary fittings such as elbows, tees etc. (as per is: 1239 part-1 (1990) wi |
| Published Date | |
|---|---|
| Due Date | 10 Mar 2026 00:00:00 |
| Estimated Value | 12.59 Lakh |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |