The DWSD Jharkhand has published a tender for "Supplying, installation, commissioning and testing of 33/11 KV, 2 MVA Power Distribution Transformer including all required accessories under D.W. and S. Mech. Urban Division, Ranchi" on the 26 Feb 2024. This tender belongs to Distribution power transformers category. This tender is published in Ranchi, Jharkhand location. The vendors interested in this tender and related Distribution power transformers tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: electrical equipments Tenders | power distribution transformers Tenders | transformers Tenders
Related categories: 66/3.3KV Power Transformer Tenders | 25KV Distribution Transformer Tenders | Power Supply Transformer Tenders |
Around 4088 tenders were floated in Jharkhand in the past month with major spending on heavy truck repair Tenders, water supply work Tenders, road construction Tenders
| Tender Title | Supplying, installation, commissioning and testing of 33/11 KV, 2 MVA Power Distribution Transformer including all required accessories under D.W. and S. Mech. Urban Division, Ranchi |
|---|---|
| Tender Description | supplying, installation, commissioning & testing outdoor type 33kv/11kv, 2 mva copper wound power transformer on load tap changer 15% to 5% in step of 1.25% with rtcc-avr and ,marshalling box. continuous rated for three phase,50 hz, full load and temperature rise not exceeding 40 degree thermometer in oil and 50 degree by the resistance in winding after continuous run at full load rating. the transformer should have oil immersed winding having vector group dy-11.hv side connected in delta and lv side connected in star with neutral brought out connected to provided separate earthing. the transformer shall have power terminal arrangement, bushing on hv side and cable end box on lv side suitable to connect xlpe aluminium cable on lv side. the transformer should have following standard fittings: the oltc shall be accomplished with:1).oil conservator with fitting hole with cap and plain oil level2) silica gel dehydrating breather charged with silica gel.3).oil drain valve.4).lifting e |
| Comments | supplying, installation, commissioning & testing outdoor type 33kv/11kv, 2 mva copper wound power transformer on load tap changer 15% to 5% in step of 1.25% with rtcc-avr and ,marshalling box. continuous rated for three phase,50 hz, full load and temperature rise not exceeding 40 degree thermometer in oil and 50 degree by the resistance in winding after continuous run at full load rating. the transformer should have oil immersed winding having vector group dy-11.hv side connected in delta and lv side connected in star with neutral brought out connected to provided separate earthing. the transformer shall have power terminal arrangement, bushing on hv side and cable end box on lv side suitable to connect xlpe aluminium cable on lv side. the transformer should have following standard fittings: the oltc shall be accomplished with:1).oil conservator with fitting hole with cap and plain oil level2) silica gel dehydrating breather charged with silica gel.3).oil drain valve.4).lifting e |
| Published Date | |
|---|---|
| Due Date | 29 Feb 2024 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |