The Jaipur PHED Chief Engineer has published a tender for "Repairing of 500 KVA Transformer at RPS Pump house Kota" on the 24 Mar 2026. This tender belongs to Transformer Services category. This tender is published in Kota, Rajasthan location. The vendors interested in this tender and related Transformer Services tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: transformers Tenders | electrical system services Tenders | electrical equipments Tenders
Related categories: Manufacturing Equipment Repair Tenders | Engineering Equipment Servicing Tenders | Packaging Machine Maintenance Tenders |
In Kota district, Rajasthan, a total of 33 Transformer Services tenders have been published, with 5 tenders released last month.
| Tender Title | Repairing of 500 KVA Transformer at RPS Pump house Kota |
|---|---|
| Tender Description | replacement of existing transformer oil confirming to is: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor) repairing of lt/ht bushings of distribution transformers including replacement of brass studs , porcelain insulators , nut bolts , oil seals , gaskets etc. complete as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . lt bushing set 500 kva ht bushing set 63 kva to 500 kva supply , installation, testing and comissioning of iso certified company made 11kv, 630a, 350 mva, on load , oil immersed metal clad load break switch complete in all respect with first filling of oil , fuses etc as required co |
| Comments | replacement of existing transformer oil confirming to is: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor) repairing of lt/ht bushings of distribution transformers including replacement of brass studs , porcelain insulators , nut bolts , oil seals , gaskets etc. complete as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . lt bushing set 500 kva ht bushing set 63 kva to 500 kva supply , installation, testing and comissioning of iso certified company made 11kv, 630a, 350 mva, on load , oil immersed metal clad load break switch complete in all respect with first filling of oil , fuses etc as required co |
| Published Date | |
|---|---|
| Due Date | 06 Apr 2026 00:00:00 |
| Estimated Value | 4.77 Lakh |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |