The Oil and Natural Gas Corporation Limited has published a tender for "REPAIRING OF HVAC SYSTEM EQUIPMENT INSTALLED AT CPF GANDHAR, ONGC ANKLESHWAR ASSET" on the 19 Jan 2026. This tender belongs to HVAC category. This tender is published in Jaipur, Rajasthan location. The vendors interested in this tender and related HVAC tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: hvac Tenders | all types of air conditioner Tenders | all civil works Tenders
Related categories: HVAC Piping Construction Tenders | HVAC Solar Energy Construction Tenders | HVAC Refrigeration Construction Tenders |
| Tender Title | REPAIRING OF HVAC SYSTEM EQUIPMENT INSTALLED AT CPF GANDHAR, ONGC ANKLESHWAR ASSET |
|---|---|
| Tender Description | at cpf process control room hvac supply and installation of lcd graphic display of chiller unit; display make - carel pgd0000f00 supply and installation of flow switch; make- honeywell, model-wfs6000, 150 psi, 1" npt, 15a, 250v in chiller unit-2, compressor overhauling, leak test (nitrogen testing) and arresting leakage if any, proper vacuum & gas charging. testing & putting chiller unit in operation with all parameters ok. servicing of manual fire damper in ahu (40000 cfm floor mounted double skin) replacement of uv lamps in ahu at cccp control room hvac shifting and installation of scroll compressors in chiller unit-1 & 2; make - danfoss, model sz185s4rc from switchyard hvac plant to ccpp hvac plant. sl no. de2502334194, de2502334188, cm2502226688 supply and installation of thermostatic expansion valve; make - danfoss, model - tgex 11tr, 38 kw, r22/r407c, 067n2177 leak test (nitrogen testing) and arresting leakage if any, proper vacuum & gas charging. testing & putting chiller unit |
| Comments | at cpf process control room hvac supply and installation of lcd graphic display of chiller unit; display make - carel pgd0000f00 supply and installation of flow switch; make- honeywell, model-wfs6000, 150 psi, 1" npt, 15a, 250v in chiller unit-2, compressor overhauling, leak test (nitrogen testing) and arresting leakage if any, proper vacuum & gas charging. testing & putting chiller unit in operation with all parameters ok. servicing of manual fire damper in ahu (40000 cfm floor mounted double skin) replacement of uv lamps in ahu at cccp control room hvac shifting and installation of scroll compressors in chiller unit-1 & 2; make - danfoss, model sz185s4rc from switchyard hvac plant to ccpp hvac plant. sl no. de2502334194, de2502334188, cm2502226688 supply and installation of thermostatic expansion valve; make - danfoss, model - tgex 11tr, 38 kw, r22/r407c, 067n2177 leak test (nitrogen testing) and arresting leakage if any, proper vacuum & gas charging. testing & putting chiller unit |
| Published Date | |
|---|---|
| Due Date | 03 Feb 2026 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |