The Rajasthan Medical and Health has published a tender for "Construction work of Sub District Hospital Building at Mandal District Bhilwara (Air Conditioning and Air Cooling work)" on the 02 Dec 2025. This tender belongs to Hospital construction service category. This tender is published in Bikaner, Rajasthan location. The vendors interested in this tender and related Hospital construction service tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: non residential buildings Tenders | all civil works Tenders | non residential buildings construction Tenders
Related categories: Bank Building Construction Tenders | Bank Repair Tenders | Fire Station Construction Tenders |
In Bikaner district, Rajasthan, a total of 3699 Hospital construction service tenders have been published, with 207 tenders released last month.
| Tender Title | Construction work of Sub District Hospital Building at Mandal District Bhilwara (Air Conditioning and Air Cooling work) |
|---|---|
| Tender Description | part "b" non bsr supply, installation, testing and commissioning of outdoor units with scroll compressor, copper condenser and required accessories for connnecting with ahu with r-407c/ r-410 refrigerant complete with controller alongwith thermostat, potential free contacts for remote operation etc. makes : daikin / blue star/ hitachi / voltas/ carrier 11 tr in twin ckt (2x5.5 tr) supplying, installing, testing and commissioning of double skin construction air handling units as per specification. ahu's shall be draw thru type, complete with pre & fine filter section including filter, minimum 6 row deep dx coil of copper tube & aluminium fins, flexible duct connection, squirrel cage induction motor, didw backward curve fan(s), belt drive, vibration isolators and mixing box for return air, fresh air. fan motor shall be suitable for 415±10% volts, 50 hz, 3 phase ac supply and shall be high efficiency (ie-2 class). ahu shall be selected for a maximum coil of 500 fpm and filter face v |
| Comments | part "b" non bsr supply, installation, testing and commissioning of outdoor units with scroll compressor, copper condenser and required accessories for connnecting with ahu with r-407c/ r-410 refrigerant complete with controller alongwith thermostat, potential free contacts for remote operation etc. makes : daikin / blue star/ hitachi / voltas/ carrier 11 tr in twin ckt (2x5.5 tr) supplying, installing, testing and commissioning of double skin construction air handling units as per specification. ahu's shall be draw thru type, complete with pre & fine filter section including filter, minimum 6 row deep dx coil of copper tube & aluminium fins, flexible duct connection, squirrel cage induction motor, didw backward curve fan(s), belt drive, vibration isolators and mixing box for return air, fresh air. fan motor shall be suitable for 415±10% volts, 50 hz, 3 phase ac supply and shall be high efficiency (ie-2 class). ahu shall be selected for a maximum coil of 500 fpm and filter face v |
| Published Date | |
|---|---|
| Due Date | 13 Dec 2025 00:00:00 |
| Estimated Value | 1.84 Crore |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |