Details: providing and fixing of false ceiling with powder coated exposed g.i. grid suspension system (e-grid t 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of main runner 3600 mm long, cross tee 1200 mm / 600 mm long and wall angle. the wall angle shall be fixed on pvc dash fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. the main runners to be placed @ 1200 mm. the cross tee 1200mm will be inserted in the pre-cut slots of main runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. additional cross tees of 600 mm shall be placed perpendicular to the cross tee 1200 mm long to finally form a grid of 600 mm x 600 mm. grid of module size 600 mm x 600 mm shall be supported by 6 mm dia g.i. wire from purlins / soffit. 4 mm thick high pressure steam cured non asbestos pearl designer fibre cement standard ceiling board (density > 1500 kg/m3) of siz