Details: conducting structural audit of building consisting of following:- scope of work:i. documentation of detailed information of existing structure.ii. as built drawings and framing plan required for modelling and sad analysisiii. visual inspection of the siteiv. ndt-non-destructive tests (as required as per as built drawings and visual inspection) ndt test details:a). rebound hammer testb). upv testc). rebar scanning testd). half cell potential ). carbonation test v. the residual life of the building should be mentioned in the final report. vi. the agency will suggest nature and type of repairs/rectifications work suggested along with methodology, sequence and extant of repairs/ retrofitting.vii. the agency will submit detail suggestions/measure to be carried out after the repair/rect