SPECIAL REPAIR REPLACEMENT TO BER TRANSF 151326739

The Military Engineer Services has published a tender for "SPECIAL REPAIR REPLACEMENT TO BER TRANSFORMER COOLING APPLIANCES AND CONNECTED ITEMS AT AF STN BORGAD UNDER GE AF OJHAR" on the 05 Aug 2026. This tender belongs to Cooling Equipment Services category. This tender is published in Nagpur, Maharashtra location. The vendors interested in this tender and related Cooling Equipment Services tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: all types of coolers Tenders | harmonic filters Tenders | industrial fans Tenders
Related categories: Heat Exchanger Repair Tenders | Heat Exchanger Retubing Tenders | Rotary Pump Repair Tenders |

Did You Know?

Around 27488 tenders were floated in Maharashtra in the past month with major spending on road construction Tenders, cc road Tenders, road relaying Tenders

Tender Details
 Tender Title / Description
Tender Title SPECIAL REPAIR REPLACEMENT TO BER TRANSFORMER COOLING APPLIANCES AND CONNECTED ITEMS AT AF STN BORGAD UNDER GE AF OJHAR
Tender Description Supply, install, testing and commissioning of floor mounted transformer copper wound of capacity 200 KVA, step down, indoor type, 50 HZ, AC, Level -2 , oil immersed naturally air cooled having no load voltage ration 11 KV/433 V complete with standard fittings, HT 11 KV/433 V corresponding to principal tapping double copper wound data connected primary side (HV) side & star connected on secondary side (LV) side in accordance with vector symbol DYN11 (Vector group - 4) with natural & having tapping on HV side for constant +5% to 10% at 2.5% step by means of manual off load tap changing arrangments, the limit of temperature rise after continuous full load run as measured by oil thermometer shall not exceed 50'C cover maximum ambient temperature prevailing at site as per IS 1180 amended up to date (Amendment 4), Total Losses at 50% load at Principal Tap at 75 º C shall be max 0.92 KW as per Level 2 of IS 1180, Total losses at 100% load at Principal Tap at 75 º C shall be max 2.7 KW as
Comments Supply, install, testing and commissioning of floor mounted transformer copper wound of capacity 200 KVA, step down, indoor type, 50 HZ, AC, Level -2 , oil immersed naturally air cooled having no load voltage ration 11 KV/433 V complete with standard fittings, HT 11 KV/433 V corresponding to principal tapping double copper wound data connected primary side (HV) side & star connected on secondary side (LV) side in accordance with vector symbol DYN11 (Vector group - 4) with natural & having tapping on HV side for constant +5% to 10% at 2.5% step by means of manual off load tap changing arrangments, the limit of temperature rise after continuous full load run as measured by oil thermometer shall not exceed 50'C cover maximum ambient temperature prevailing at site as per IS 1180 amended up to date (Amendment 4), Total Losses at 50% load at Principal Tap at 75 º C shall be max 0.92 KW as per Level 2 of IS 1180, Total losses at 100% load at Principal Tap at 75 º C shall be max 2.7 KW as
 Important Dates
Published Date
Due Date 26 Aug 2026 18:00:00
Tender Open Date
 Estimate and EMD
Estimated Value 24.32 Lakh
EMD 48700 INR
Processing Fee 500 INR
 Tender No

TSID: 151326739

 Tender Type and Location
Tender Category
Location/Region
Tender Type
WhatsApp Chat