The Greater Mumbai Municipal Corporation has published a tender for "Refurbishment of ICCP system installed near Poisar Depot, Kandivali (West), Mumbai - 400067" on the 30 Oct 2025. This tender belongs to Cathodic Protection System Repair category. This tender is published in Mumbai, Maharashtra location. The vendors interested in this tender and related Cathodic Protection System Repair tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: cathodic protection monitoring Tenders | all types of automation system Tenders | srp automation Tenders
Related categories: Plastic Coating of Concrete Structures Tenders | Anode Cathodic Protection Tenders | Corrosion control service Tenders |
Greater Mumbai Municipal Corporation issued 12 tenders for Cathodic Protection System Repair last year
With, 0 floated just last month.
| Tender Title | Refurbishment of ICCP system installed near Poisar Depot, Kandivali (West), Mumbai - 400067 |
|---|---|
| Tender Description | refurbishment of iccp system installed near poisar depot, kandivali (west), mumbai - 400067 foundation for outer cubical panel for 50 v / 50 a output rating ac operated automatic cp transformer rectifier unit (tr unit) as per sor r3-he-15-21, technical specifications. supply 1c x 16 mm² annealed bare copper conductor as per usor r3-he-15-14, technical specifications. supply of 4c x 6 mm² annealed bare copper conductor as per usor r3-he-15-15, technical specifications. supply of 4c x 10 mm² annealed bare copper conductor as per usor r3-he-15-17, technical specifications. maintenance free chemical earthing as per usor r3-he-15-23, technical specifications. foundation for ms power supply box required for cathodic protection system along with accessories as per sor r3-he-15-25, technical specifications. liasoning for successful installation & commissioning of entire corrosion protection system as per usor r3-he-15-28, technical specifiactions commissioning of overall cathodic protection sy |
| Comments | refurbishment of iccp system installed near poisar depot, kandivali (west), mumbai - 400067 foundation for outer cubical panel for 50 v / 50 a output rating ac operated automatic cp transformer rectifier unit (tr unit) as per sor r3-he-15-21, technical specifications. supply 1c x 16 mm² annealed bare copper conductor as per usor r3-he-15-14, technical specifications. supply of 4c x 6 mm² annealed bare copper conductor as per usor r3-he-15-15, technical specifications. supply of 4c x 10 mm² annealed bare copper conductor as per usor r3-he-15-17, technical specifications. maintenance free chemical earthing as per usor r3-he-15-23, technical specifications. foundation for ms power supply box required for cathodic protection system along with accessories as per sor r3-he-15-25, technical specifications. liasoning for successful installation & commissioning of entire corrosion protection system as per usor r3-he-15-28, technical specifiactions commissioning of overall cathodic protection sy |
| Published Date | |
|---|---|
| Due Date | 10 Nov 2025 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |