The The Fertilisers And Chemicals Travancore Ltd. has published a tender for "Leak testing of W2 and W5 Heat Exchanger and other miscellaneous mechanical works in SAP, FACT-CD during ATA 2026." on the 31 Mar 2026. This tender belongs to Heat Exchanger Repair category. This tender is published in Ernakulam, Kerala location. The vendors interested in this tender and related Heat Exchanger Repair tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: heat exchangers Tenders | air coolers Tenders | consumer durables Tenders
Related categories: Heat Exchanger Repair Tenders | Heat Exchanger Retubing Tenders | Rotary Pump Repair Tenders |
Kerala has published 10 tenders in Heat Exchanger Repair in the last financial year.
Out of these, 2 were published last month.
| Tender Title | Leak testing of W2 and W5 Heat Exchanger and other miscellaneous mechanical works in SAP, FACT-CD during ATA 2026. |
|---|---|
| Tender Description | leak testing of w2 & w5 heat exchanger and other miscellaneous mechanical works in sap, fact-cd during ata 2026. closing and opening at w2 outlet:closing of w2 outlet vent , 800 nb, with proper gasket inorder to have a leak free joint before leak test and then opening it after leak testing. providing slipplates at w5 inlet & outlet ducts and removal - the work involves cutting of w5 shell inlet duct from iat,w5 shell outlet to w2 for for providing slip plates after giving necessary supports as per instruction of the site engineer. slip plate provided in w5-w2 duct & w5-iat inlet duct shall ensure proper isolation of w2 & w5 vessels before testing. after testing slip plates shall be removed and ducts shall be welded back without any leaks as per instruction from engineer - in charge. any welding cutting etc involed in the process shall be under the scope of the contractor.all scaffolding and other site arrangements for the execution of the work shall be under the scope of work o |
| Comments | leak testing of w2 & w5 heat exchanger and other miscellaneous mechanical works in sap, fact-cd during ata 2026. closing and opening at w2 outlet:closing of w2 outlet vent , 800 nb, with proper gasket inorder to have a leak free joint before leak test and then opening it after leak testing. providing slipplates at w5 inlet & outlet ducts and removal - the work involves cutting of w5 shell inlet duct from iat,w5 shell outlet to w2 for for providing slip plates after giving necessary supports as per instruction of the site engineer. slip plate provided in w5-w2 duct & w5-iat inlet duct shall ensure proper isolation of w2 & w5 vessels before testing. after testing slip plates shall be removed and ducts shall be welded back without any leaks as per instruction from engineer - in charge. any welding cutting etc involed in the process shall be under the scope of the contractor.all scaffolding and other site arrangements for the execution of the work shall be under the scope of work o |
| Published Date | |
|---|---|
| Due Date | 07 Apr 2026 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |