Details: "repairing of oil-water separator and subsequent trials to the satisfaction of irs. equipment: 15ppm bilge separatormake: blohm + voss industries (german)type : turblo – mpbcapacity: 0.5 cu.m/phrpower source – 415, 50 hz 3-phase, 0.8pfa) supply, fitment and trial of 15ppm monitor along with circuit board.b) ows pump with gear box and motor needs to be overhauled along with new service kit except stator assy.c) an additional strainer fitment provision to be made in the suction line including supply of suitable strainer.""a) cross over valve 04 nos. of water and foam monitor of fifi on monkey deck is found leaking. the same has to rectify. b) monitoring block is found corroded and needs renewal."415v/230v/24v dc earth fault showed at msb and distribution board (as per attached megger test report). needs rectification."sewage treatment plant:equipment: sewage treatment plant (stp)make: warsila – water system ltd. (uk)plant type – stc 01 – 13power source – 415v, 50-60 hz, 3 phase, 0.92 kw,