The Employees State Insurance Corporation has published a tender for "BODYPLETHESMOGRAPHY (BODYPLETHESMOGRAPHY)" on the 22 Aug 2022. This tender belongs to Body plethysmograph category. This tender is published in Faridabad, Haryana location. The vendors interested in this tender and related Body plethysmograph tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: pulmonary function testing or pft products Tenders | medical equipments Tenders | biomedical equipment Tenders
Related categories: Peak flowmeter Tenders | Sleep Study Monitor Tenders | Transcutaneous Monitor Tenders |
Around 8344 tenders were floated in Haryana in the past month with major spending on unit paving Tenders, community hall construction Tenders, food grain transport Tenders
| Tender Title | BODYPLETHESMOGRAPHY (BODYPLETHESMOGRAPHY) |
|---|---|
| Tender Description | TECHNICAL SPECIFICATION OF BODYPLETHESMOGRAPHYBodybox (Plethesmography Machine)1. A wide cabin with internal volume range of > 900 litres to provide ease of accessibility andcomfort to the patient without effecting volume changes.2.Transparent robust glass walls to ensure visibility from all sides and minimize any claustrophobicfeeling for the patient.3.The seat must be ergonomic, comfortable and adjustable or fixed bench in height to bear weightup to 150Kg.4.The arm for the breathing valve support must be flexible enough to allow tests execution evenoutside the cabin.5.Controlling station should be on a movable trolley.6.Speaker and mike facility inside box for communication with the patientI. Test and minimum set of parameter required –Dynamic lung volumes: Measurement of the Forced Vital Capacity (FVC), Slow Vital Capacity (SVC)and Maximal Ventilatory Ventilation (MVV). Graphic display of Flow/volume, Volume/time loops.Bronchial challenge test :a)Measurement of the response to Bronc |
| Comments | TECHNICAL SPECIFICATION OF BODYPLETHESMOGRAPHYBodybox (Plethesmography Machine)1. A wide cabin with internal volume range of > 900 litres to provide ease of accessibility andcomfort to the patient without effecting volume changes.2.Transparent robust glass walls to ensure visibility from all sides and minimize any claustrophobicfeeling for the patient.3.The seat must be ergonomic, comfortable and adjustable or fixed bench in height to bear weightup to 150Kg.4.The arm for the breathing valve support must be flexible enough to allow tests execution evenoutside the cabin.5.Controlling station should be on a movable trolley.6.Speaker and mike facility inside box for communication with the patientI. Test and minimum set of parameter required –Dynamic lung volumes: Measurement of the Forced Vital Capacity (FVC), Slow Vital Capacity (SVC)and Maximal Ventilatory Ventilation (MVV). Graphic display of Flow/volume, Volume/time loops.Bronchial challenge test :a)Measurement of the response to Bronc |