Details: demolition of brick work and concrete like coping etc built in cm completed all as specified and directed. excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil as directed. m&l for cement concrete type c2 1:4:8 (40mm graded aggregates) in foundation filling and mass concrete all as specified and directed m&l for form work rough finished surfaces of concrete side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work flat, vertical complete all as specified m&l for form work to sides of pillar, posts, struts, columns etc all as specified and directed m&l for form work to sides and soffits of beams lintel band and the like all as specified and directed. m&l for rcc m-25 design mix (using 20 mm graded stone agg) in foundation, footings, etc all as specified and directed m&l for rcc m-25 reinforced