Details: taking out motor from base frame and transporting into local workshop for re-winding of cf / monoblock electrical motor by disconnecting electrical & mechanical connections, opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with supper enameled copper wire / insulated copper winding wire as per the existing gauge, replacement of bearing and fan incl reassembling, testing and commissioning of electric motor on full load capacity of 5hp, three phase 415volts 50 hz including repair to pump by replacing unserviceable bearings of existing size and lathe work if required and refixing the same complete all as specified by engineer-in-charge. all as per srl no. 1 here in before but for cf / monoblock electric motor of capacity of 3hp, complete all as specified by engineer-in-charge. all as per srl no. 1 here in before but for submersible/cf / monoblock electric motor of capacity 0.5 to 1 hp, complete all as specified by engineer-in-charge.
Sector: Defense