Details: egcuitem required for paras 125kva-iitechnical specification :-1. operating voltage – 24v dc2. stead stability - ± 0.25% or better3. actuator current – 10 amps4. speed sensor signal – 1-120v ac5.droop range – 1-5% regulation6. protection inbuilt – low oilpressure safety for engine shut down.7. features required :- (a) over speed led indication (b) selectable droop operation (c) reverse voltage protection (d) auxiliary accessory inputs8. warranty :- 12 months