Details: lrp/011 asv section kg5h-230defect-:1. unusual noise from mechanical lubricator.2. air leak from dryer filter.3. pressure not building more than 150 kg/cm².scope of work-:(a) repair of mechanical lubricator, centrifugal clutch and gear alignment with compressor.(b) both filters seals to be replaced and to make leak proof. air dryer desiccant (molecular sieve and pearls) to be replaced.(c) all 5 stages suction and delivery valves to be serviced and repair/replacement if faulty. delivery pressure should bullpup up to be 210 kg/cm² without any leakage.(d) safety valve to be repaired/replaced if any defective(e) new charging hose to be fitted with adaptor.
Sector: Defense