Details: in order for the cypres (military) to function effectively it has to undergo the following checks and the all the parameters mentioned below for operation need to be re-assessed: -(a) permanent preset activation altitude: 1500 ft agl(b) activation speed at 35 m/sec or 78 miles/hr(c) working temperature between -20°c to 60°c(d) humidity checks at 99%.(e) waterproof up to 12 hours at 5 ft depth(f) maintenance cycle not less than 04 years(g) operating range between -1500 ft to 30000 ft agl(h) re-calibration checks(j) replacement of batteries for continued operations
Sector: Defense