Details: charges for upkeeping and maintenance of mill reject handling system round the clock, including over size and bypass valve manual operation, removing of accumulated rejects in the trench, cleaning of coal / mill rejects, choke in pyrite hoppers etc., including cost of consumables and hire charges for tools & plants. charges for lubricating the valves such as mill reject inlet valves, over size valves, by pass valve, checking the connected pipe lines and valves, arresting leaks if any including cost of consumables and hire charges for tools and plants. charges for atteding defects in pyrite hoppers inlet valves, oversize valves and other operating valves by arresting the pipes, dismantling the valves from its position, dismantling and removing the valve seals, cleaning the cylinder, reassembling the new seal kit & lubricating the cylinder, refixing the rectified valves in its position and checking the valve operation including cost of consumables and hire charges for tools and plants.
Sector: Power Sector