Details: technical specification of experimental setup to observe critical point of liquid gas mixture (1 setup)srl name of the item specification/tech. details quantity1 pressure chamber fordemonstrating the criticaltemperaturefilling: sf6 , sulphur hexafluoridecritical temperature of liquidfilling: 45.5 °c = 318.7 kcritical pressure of liquid filling: 37.6 bar = 37,600hpamax. temperature rating of the gaskets: 100 °cdimensions of the chamber: 5 cm x 5 cm x 6 cmstand rod length: 12 cm x 10 mm diam.hose diameter: 8 mmas required2 lamp housing with cable socket: e 14connection: 6 v (cable with 4 mm safety plugs)length: 12 cm (folded)length of tube: 6 cmdiameter: approx. 7 cmrod diameter: 10 mmas required3 bulbs voltage: 6 vcurrent: 5 apower: 30 wsocket: e14as required4 condenser with diaphragmholdercondenser:focal length: approx. 50 mmdiameter: 60 mmdiaphragm holder:rail spacing: 50 mmopening: 45 mm x 45 mmfastening pins: 4 mm diam.5 diaphragms and image objects:hole diameter: 6 mm and 12 mmsl