Details: wiring for circuit submain wiring along with earth wire with the following size pvc insulated copper conductor , single core cable in surface / recessed pvc conduit etc as reqd . a) 2x4 sq mm + 1x4 sq mm earth wire (for power wiring) b) 5x6 sq, mm. (for nic office) rewiring for light point/fan point/exhaust fan point/ call bell point 1.5 sq.mm fr pvc insulated copper conductor single core cable in existing surface / recessed steel/pvc conduit including dismantling as required group - c supplying and fixing of following modular switch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps, one way switch 5/6 amps, 3 pin socket outlet 15/ 16 amps, one way switch 15/16 amps, 6 pin socket outlet supplying and drawing following sizes of fr pvc insulated copper conductor single core cable in existing surface / recessed steel / pvc conduit including dismantling as required 3 x 1.5 sq.mm 3 x 2.5 sq.mm
Sector: Renewable Energy