Details: disconnecting of all motor leads, dismantling of motor, taking out the rotor from the stator, and complete disassembly as per requirement of job: mechanical transportation, loading, unloading and handling of 60 hp motor from site to workshop and vice versa using load carrier auto. complete rewinding of stator coils of 3-phase lv horizontal/ vertical induction motor with suitable copper wire after complete removal of burnt out winding, cleaning of slots, etc. by way of providing, preparation and fitting of new copper coils of electrolytic grade copper wire windnigs having f- class in place of damaged coils including allied jobs such as varnishing, drying etc - per kg of winding. deduct the cost of old copper scrap retreived from the motor @90% or as per actual.note: the unserviceable scrap copper windings extracted shall be property of the firm and is taken into account for estimation of rates(the amount quoted against the item has to be not less than rs. 650). assembling of all motor
Sector: Irrigation