Details: as per annexure : iv-a of nit i.e. each site i.e. turbine & its auxs site, pump site, regenerative site and misc sites are to manned individually with a team of foreman (highly skilled), technician (skilled-b),fitter , helpers (semi skilled-b) for each unit . highly skilled supervisor, welder gas cutter (highly skilled), crane operator for both units. the contractor would station adequate working manpower in such a way that the maintenance work is carried out effectively and without any delay round the clock. (firm quote common rates for each month for both units) replacement of mech. seals of bfp/bp alignment of bp/ motor nde bearing inspection for bfp/bp de bearing inspection of bfp/bp & bfp motor suction ‘o’ ring replacement discharge ‘o’ ring replacement alignment checking & correction of hydraulic coupling & bfp attending of parting plane leakage of booster pump replacement of bfp cartridge cooling water jacket cleaning of bfp/ booster pump checking of bearing of hydraulic cou
Sector: Urban Authority