Details: the equipment should be able to detect mobile bands, wifi and bluetooth in the spectrum from 10khz to 6 ghz. the following requirements should be met with this equipment:1. it should display a full range of frequency data including span, start and stop frequencies, db, andrbw between 10 khz to 6 ghz. types of signal graphs include live trace, peak trace, cachedpeak™, average trace, alert threshold, rssi, o-scope and more.2. it should have smartbars™ mode to detect and locate rf energy by displaying new signals, orincreased rf energy, compared to a reference trace from outside the target sweep area. newenergy is indicated by an increase in certain bars.3. it should have mobile bands mode to quickly and easily monitor rf energy levels for multiplespecific rf bands (i.e. wifi, gsm, etc.) on one screen. each band should be customizable touser defined spans.4. it should have wifi and bluetooth® modes to display nearby wifi access points and bluetooth®pairings, relative signal strength, and