The RWF has published a tender for "Digital/Numerical 3-phase" on the 26 Dec 2024. This tender belongs to Electrical Equipments category. This tender is published in Bangalore, Karnataka location. The vendors interested in this tender and related Electrical Equipments tenders can obtain further details by exploring Tendersniper web portal. Tendersniper sends regular tender alerts by email specifically addressing the user requirements (i.e., keywords, location and value range). Government business is a growing area of opportunity. The businesses are encouraged to actively monitor tender opportunities and participate in them to grow their business.
Related alert: electrical equipments Tenders | electric meter boxes Tenders | all types of buoys Tenders
Karnataka has published 944 tenders in Electrical Equipments in the last financial year.
Out of these, 83 were published last month.
| Tender Title | Digital/Numerical 3-phase |
|---|---|
| Tender Description | description :technical specification for digital/numerical 3-phase overcurrent + earth fault protection relay 1. auxiliary supply : 24-240 v dc 2. current input : 1 amps or 5 amps site programmable 3. frequency :50 hz 4. time current characteristics : ni1.3, ni3, vi, ei, definite time 5. site selectable iec curves : 4 nos.of idmt curves + definite time characteristics 6. indication : leds for fault trip indication 7. trip record : minimum last 5 trip records with date and time stamping 8. protection functions : lowset overcurrent, highsetovercurrent, lowset earth fault, highset earth fault 9. o/c low set settings : 20 to 200% of nominal currentin step of 1% 10. e/f low set settings : 5 to 80% of nominal current in step of 1% 11. tms : 0.01 to 1.60 instep of 0.01 12. o/c high set : disable, 0.2 to 20 times of nominal current 13. e/f high set : disable, 0.05 to20 times of nominal current 14. o/c & e/f high set delay : disable, 0.05, 0.1 to 2 sec in step of 0.01 15. output contacts : mini |
| Comments | description :technical specification for digital/numerical 3-phase overcurrent + earth fault protection relay 1. auxiliary supply : 24-240 v dc 2. current input : 1 amps or 5 amps site programmable 3. frequency :50 hz 4. time current characteristics : ni1.3, ni3, vi, ei, definite time 5. site selectable iec curves : 4 nos.of idmt curves + definite time characteristics 6. indication : leds for fault trip indication 7. trip record : minimum last 5 trip records with date and time stamping 8. protection functions : lowset overcurrent, highsetovercurrent, lowset earth fault, highset earth fault 9. o/c low set settings : 20 to 200% of nominal currentin step of 1% 10. e/f low set settings : 5 to 80% of nominal current in step of 1% 11. tms : 0.01 to 1.60 instep of 0.01 12. o/c high set : disable, 0.2 to 20 times of nominal current 13. e/f high set : disable, 0.05 to20 times of nominal current 14. o/c & e/f high set delay : disable, 0.05, 0.1 to 2 sec in step of 0.01 15. output contacts : mini |
| Published Date | |
|---|---|
| Due Date | 06 Jan 2025 00:00:00 |
| Estimated Value | 0.0 |
|---|---|
| EMD | 0 INR |
| Processing Fee | 0 INR |